Parameters of standard FRP centrifugal fan

  • Fan type JTF-11.2C
  • Applicable air volume 17034-(m³/h)
  • Applicable wind pressure 1174-4964(Pa)
  • Applicable revolutions 900-1450(rpm)
  • Applicable power 14.4-101.1(Kw)
  • Fan weight (excluding motor)
  • Applicable working temperature

      -20℃~60℃(Standard)

    -20℃~100℃(High temperature)

  • Outline size

    AB:2800*2460*2600

    CD:2800*2460*2600

    EF:2800*2460*2510

  • Model annotation
  • How to select
  • Precautions for fan installation
  • Fan maintenance manual

JTF-11.2C型号注解.jpg

1. Selection process

image.png 

2. Selection content

(1) Air volume: determined by the air volume required by the system;

(2)Total pressure: determined by the resistance of pipeline system and equipment;

(3) Angle of inlet and outlet: determined by the direction of inlet and outlet;

(4) Optional direction: determined by the pipeline system;

(5) Transmission mode: determine the transmission efficiency. The mechanical efficiency of the direct drive of the motor, the direct drive of the coupling and the belt drive are 1, 0.98 and 0.95 respectively.

(6) When selecting the fan, the air leakage and resistance calculation error due to the lax ventilation pipe system shall be considered. In order to make the fan operate reliably, the air volume and pressure of the system shall be reserved.

Air volume and air pressure margin selection table


Air supply and exhaust system

Air leakage

Additional resistance of pipe network

General air supply and exhaust system

5%-10%

10%-15%

Dust removal system

10%-15%

15%-20%

Boiler blower system

5%-10%

10%-15%

    Precautions for fan installation


  1. Determine the rationality of the installation position and select the correct installation size.

  2. All bolt holes on the air duct support shall be drilled, and gas welding is not allowed.

  3. On the basis of correctly fixing the fan, the vibration of the fan will be increased due to the pollution during the rotation of the fan, so it is necessary to use bolts of appropriate size to fix the fan on the basis of planning to fix the fan.

  4. When installing the shockproof pad, the shockproof pad shall be installed on the fan first, and then the position of the bolt hole shall be drawn on this basis, so as to prevent the rubber of the shockproof pad from being forced and twisted.

  5. After the fan is fixed, the anchor bolt hole of secondary grouting is required. Pea stone concrete should be used for secondary grouting, and cement mortar should not be used to pour holes.

    Fan maintenance manual


  1. The fan shall be stored in a dry and ventilated indoor place to prevent the motor from getting damp; the fan stored in the open air shall be provided with protective measures to prevent rainwater and other sundries from entering the fan.

  2. For fans that have been stored for a long time, the rotating parts of the fans shall be derusted every month and coated with antirust oil to prevent rusting.

  3. The fan blades shall be cleaned regularly to extend the service life of the fan.

  4. Before starting the fan, make sure that the ventilation device at the inlet and outlet of the ventilation system is in the open state, so as to avoid the fan motor being burned due to the long-term back pressure.

  5. In case of abnormal sound, serious heating of motor, electrified shell, tripping of switch, etc. during the operation of the fan, the fan shall be shut down immediately for inspection. Restart the machine after confirming that there is no error.

  6. The use environment of the fan should always be kept clean, the surface of the fan should be kept clean, the inlet and outlet of the ventilation system should be free of sundries, and the dust and other sundries in the fan and the pipeline should be removed regularly. If there is an air filter, it should be cleaned regularly.

  7. According to the use environment and the actual situation, supplement or replace the wet wheel grease for the bearing irregularly.

Installation diagram Please click to download the detailed size drawing

Pay attention to the public number Get the extraction code.

0001.jpg

Fan performance selection parameter table

JTF-11.2CP=1.2kg/m3T=20℃
Pa496449144789459043163968354430461450rpm
m3/h2744433250390554486150666564726227768083
Kw60.5 67.7 74.5 80.8 86.6 91.9 96.8 101.1 
Pa328832543172304028582628234720181180rpm
m3/h2233427058317833650741232459565068055405
Kw32.6 36.5 40.1 43.5 46.6 49.5 52.1 54.5 
Pa306830382960283726682452219118831140rpm
m3/h2157726141307053527039834443984896353527
Kw29.4 32.9 36.2 39.2 42.1 44.6 47.0 49.1 
Pa285728282756264224842283204017531100rpm
m3/h2082025224296283403238436428404724551649
Kw26.4 29.6 32.5 35.2 37.8 40.1 42.2 44.1 
Pa265326262560245323072120189416281060rpm
m3/h2006324307285513279537039412834552749771
Kw23.6 26.4 29.1 31.5 33.8 35.9 37.8 39.5 
Pa245624322370227121361963175415071020rpm
m3/h1930623389274733155735641397254380947893
Kw21.0 23.6 25.9 28.1 30.2 32.0 33.6 35.2 
Pa22682245218820971972181216191392980rpm
m3/h1854822472263963032034243381674209146014
Kw18.6 20.9 23.0 24.9 26.7 28.3 29.8 31.2 
Pa20862065201319291814166714901280940rpm
m3/h1779121555253182908232846366094037644136
Kw16.5 18.4 20.3 22.0 23.6 25.0 26.3 27.5 
Pa19121893184517681663152813651174900rpm
m3/h1703420638242412784531448350513865542258
Kw14.4 16.2 17.8 19.3 20.7 21.9 23.1 24.1 


image.png